Connect
Created by EBCCW 00:06
5
5113270
5 Connect
There are two possibilities to connect to the motors.
5.1 Internal bus, B-bus
The first alternative is to connect directly to each motors internal bus, B-
bus. Then you connect the laptop with the USB dongle to the motor (con
-
nection X2) via the adapter cable (Festo, D-sub to M12). In the parameter
software you chose B-bus on the interface menu. The tool can only reach
the connected motor. In order to download the ECO software you have to
use this alternative.
Figure 1 B-Bus
5.2 External bus, A-bus
The second alternative is to connect to the external bus (A-bus) instead. In
this case you have to disconnect a line control master because there has
to be only one CANopen master on the network simultaneously. It is impor
-
tant to keep the network powered up if the line controller master is discon-
nected.
Picture: Power on CANopen network